Memopower Li Series with Lithium Batteries
1~3kVA PF:0.9
The Memopower Li series online UPS with LiFePO4 Lithium Batteries features long service time and high density. With smart battery management system it can improve the overall performance of the UPS and lengthen the warranty. This Long-life-span lithium-ion UPS can also shift your refresh cycle to be in line with your IT equipment, saving time and money spent on labor and replacement batteries.
General Features
●Ture Online DoubleConversion
●Lithium-ion Batteries built-in
●Smart BMS provides up-to-date insight
●Reduce Weight,improved performance and Lengthened Warranty
●Wide input voltage range for harsh environment
●Support generator
●Output power factor 0.9
●Up to 92% efficiency models available
●UL certificated
Technical Specification
MODEL | MP RT 1k S | MP RT 1.5k S | MP RT 2k S | MP RT 3k S | |||||
Capacity | 1000VA/900W | 1000VA/1000W | 1500VA/1350W | 2000VA/1800W | 3000VA/2700W | ||||
INPUT | |||||||||
Nominal voltage | 100/110/115/120/125 Vac | ||||||||
Input voltage range | 55~150 Vac (80~150Vac @ 100% load) | ||||||||
Power factor | >0.99 (Full load) | ||||||||
Input connection | NEMA 5-15P | NEMA 5-20P | NEMA L5-30P | ||||||
Cord length | 1.8m | ||||||||
FREQUENCY | |||||||||
Frequency range | 40~70Hz (50/60Hz Auto-Sensing) | ||||||||
OUTPUT | |||||||||
Output voltage | 100/110/115/120/125 Vac | ||||||||
Voltage regulation | ±1% | ||||||||
Power factor | 0.9 1.0 0.9 | ||||||||
Output frequency | Line mode | 50/60Hz ± 4Hz | |||||||
Bat. mode | 50/60Hz ± 0.02Hz | ||||||||
Crest factor | 3:01 | ||||||||
Harmonic distortion (THDv) | ≤3% Full linear load | ≤2% Full linear load | |||||||
≤4% Full non-linear load | |||||||||
Transfer time | AC mode to Bat.mode | 0ms | |||||||
Inverter to Bypass | 4ms (Typical) | ||||||||
Output waveform | Pure Sinewave | ||||||||
Output receptacles | Programmable (Optional) | 5-15R×4 | 5-20R×4 | 5-20R×3 | |||||
Non-programmable | 5-15R×4 | L5-20R×1 (Optional) + 5-20R×4 | L5-30R×1+5-20R×3 | ||||||
EFFICIENCY | |||||||||
AC mode | 91% | 91% | 92% | 92% | |||||
ECO mode | 95% | 95% | 96% | 96.50% | |||||
BATTERY | |||||||||
Battery number | 2 | 3 | 3 | 4 | 4 | 6 | 6 | ||
Battery capacity | 9Ah/12V | ||||||||
Typical recharging time | 4hours (To 90% of full capacity) | ||||||||
Charging voltage | 27.14 Vdc±1% 41.1 Vdc±1% 54.8 V | dc±1% | 82.2 Vdc±1% | ||||||
Charging current (Max.) | 2A | ||||||||
INDICATORS | |||||||||
LED / LCD display | Line mode, Bat.mode, ECO mode, Bypass mode, Battery low voltage, Overload & UPS fault | ||||||||
ALARM | |||||||||
Battery mode | Beeping every 4 seconds | ||||||||
Battery low | Beeping every second | ||||||||
Overload | Beeping twice every second | ||||||||
Fault | Continously beeping | ||||||||
PHYSICAL | |||||||||
Dimension W×D×H | 440×325×86.5mm | 440×460 | 86.5mm | 440×500×86.5mm | 4 | 40×640×86.5mm | |||
Net weight | 14kg | 16.5kg | 17kg | 19.5kg | 21kg | 26.7kg | 27kg | ||
ENVIRONMENT | |||||||||
Operating temperature | 0~40 ºC | ||||||||
Storage temperature | -25℃~55℃ (Without batteries) | ||||||||
Humidity range | 0~95% (Non - condensing) | ||||||||
Altitude | 0~3000 (1000~3000 derating required) | ||||||||
Noise level | ≤45dB | ≤55dB | |||||||
STANDARDS | |||||||||
Safety | UL1778 5th Edition CSA C22.2 NO.107.3-14 | ||||||||
FCC | FCC Part 15, Subpart B, ClassB ANSI C63.4-2014 | FCC Part 15, Subpart B, ClassA ANSI C63.4-2014 | |||||||
Energy saving | Energy Star 2.0 | ||||||||
Transportation | ISTA Procedure 2A |